Facilities

Epifluorescence Microscopes

Zeiss Axioskop II Plus
Zeiss Axioskop II plus
Filter sets: UV (Filter set 02); Blue (Filter set 10); Green (Filter set 15)
Camera: AxioCam MRc camera
Other features: ASI motorized stage, stereology package
Contact Person: Matt Pitts
Location: Biosciences Bld. room 217

 
Olympus IX81 DSU spinning disk
Olympus IX81 spinning disc
Light Source: 12 bit Prior Lumen200 (200 Watt metal arc lamp)
Filter sets: 330-385nm ex/420nm em; 450-480nm ex/515nm em; 510-550nm ex/590nm em
Camera: Hamamatsu CCD Camera; 15 f.p.s.; 1344 x 1024 resolution
Other features: spinning disk, 3D imaging, environmental chamber
Contact Person: Matt Pitts
Location: Biosciences Bld. room 217

Olympus IX81
Olympus IX81
Filter sets: UV (UN31000v2), Blue (UN41001), Gr-Yellow (UN41004)
Camera: Hamamatsu Orca-R2
Other features: ASI motorized stage, environmental controls
Contact Person: Chris Farrar
Location: UH Cancer Center Bld. room 132

Olympus IX71
Olympus IX71_2
Filter sets: UV (U-MWU2), Blue (U-MWB2), Green (U-MWG2), IY (U-MWIY2)
Camera: Zeiss Axiocam HRm
Contact Person: Matt Pitts
Location: Biosciences Bld. room 217

Olympus IX71
Olympus IX71_1
Filter sets: UV (UN31000v2), Blue (UN41001), Gr-Yellow (UN41004)
Camera: Q-Imaging Retiga 2000R
Contact Person: Chris Farrar
Location: UH Cancer Center Bld. room 132

Zeiss Axioimager
Zeiss Axioimager
Filter sets: UV (UN31000v2), Blue (UN41001), Gr-Yellow (UN41004)
Camera: Zeiss Axiocam HRm
Contact Person: Matt Pitts
Location: Biosciences Bld. room 217

Zeiss Axioplan
Zeiss Axioplan
Filter sets: UV (UN31000v2), Blue (UN41001), Gr-Yellow (UN41004)
Camera: Coolsnap CCD color camera
Contact Person: Chris Farrar
Location: UH Cancer Center Bld. room 132

Nikon Diaphot
Nikon Diaphot
Filter sets: UV (UN31000v2), Blue (UN41001), Gr-Yellow (UN41004)
Camera: Microfire CCD color camera
Contact Person: Chris Farrar
Location: UH Cancer Center Bld. room 132

 
Laser Scanning Confocal Microscopes

Leica TCS SP5
Leica SP5
Laser Lines: 405, 458, 476, 488, 496, 514, 543, 594, 633 nm
Channels: 3 spectral PMT’s (400-800 nm) + 1 transmitted light PMT
Excitation Modulation/Emission Splitting: AOTF/ AOBS®
Other features: motorized stage, incubation system, FRET & FRAP
Contact Person: Chris Farrar
Location: UH Cancer Center Bld. room 132A

Nikon Chameleon
Nikon Chameleon LSM
Laser Lines: 405, 457, 488, 514, 552 nm
Channels: 3 spectral PMT’s (400-800 nm)
Excitation Modulation/Emission Splitting: AOTF/dichroic mirrors
Contact Person: Matt Pitts
Location: Biosciences Bld. room 217

 

Zeiss LSM 5 Pascal
Zeiss LSM 5 Pascal
Laser Lines: 488, 514, 543, 633 nm
Channels: 2 spectral PMT’s (400-800 nm)
Excitation Modulation/Emission Splitting: MOTF/dichroic mirrors
Contact Person: Matt Pitts
Location: Biosciences Bld. room 217

 
Other Analysis & Imaging Systems

BD LSRFortessa Flow Cytometer
BD LSRFortessa
Laser Lines: 405, 488, 561, 633 nm
Channels: 16 PMT’s
Other features: HTS 96-well plate autosampler
Contact Person: Chris Farrar
Location: Biosciences Bld. room 330

 
BD Accuri C6 Flow Cytometer
BD Accuri C6
Laser Lines: 488 & 633 nm
Channels: 4 PMT’s
Other features: CSampler 96-well plate autosampler
Contact Person: Chris Farrar
Location: UH Cancer Center Bld. room 130

 

MMI CellCut Plus Laser Microdissection System
MMI Laser Microdissection
CellCut Laser Line: 350 nm
Microscope: Olympus IX81
Other features: draw-on screen w/ pen; CellEctor system
Contact Person: Chris Farrar
Location: UH Cancer Center Bld. room 132A

IVIS Lumina Small Animal Imaging System
IVIS Lumina

Contact Person: Chris Farrar
Location: Biosciences Bld. room 146

 

 
Li-Cor Odyssey IR Imaging System
Li-Cor Odyssey Imager

Contact Person: Matt Pitts
Location: Biosciences Bld. room 205